Smart Power Meter Hack

A group of Dutch scientists have been testing out some of today’s “smart” electrical meters to check their accuracy, among other things. Not ones to disappoint, the scientists have found consistently With experiments lasting for six months, the researchers tried to focus on meters representative of those commonly used in the Netherlands and manufactured between 2004 and 2014. Moreover, the researchers tried to reproduce standard household energy consumption patters rather than focusing on stress tests. Their results? Well, “results varied wildly, with some meters reporting errors way above their disclosed range, going from -32% to +582%. Vray For 3ds Max Design 2012 64 Bit Free Download. Tests with uncommon results were repeated several times and the results were within a few percents of the original.” Moreover, “The greatest inaccuracies were seen when researchers combined dimmers with energy saving light bulbs and LED bulbs.” Not constrained to energy saving light bulbs, the inaccuracies are, ironically, tied to devices with integrated energy saving features.

(Certainly makes us want to keep a ) “The reason for faulty readings appears to be the current sensor, and the associated circuitry,” said researchers. “The experimental results [] show that static energy meters can be pushed into faulty reading (positive and negative) if sufficiently fast pulsed currents are drawn by the consumer” It is worth noting that there is contradictory research published by “the European voice of the providers of smart energy solutions” that maintains that “there is no reason to question smart metering technology”. Still, we wouldn’t blame you if you. Thanks [acs] for sending this in! Posted in, Post navigation.

One of the problems with current sensors used in meters is that they are cheap and doesn’t have the frequency response to handle some high-frequency loads. The frequency response on CT sensors are usually less than the 8th harmonic (. Iso 105-e04 1994. So if a current transformer is no good, would the old fashioned method be better? IE an inline resistor? When I say resistor I suppose I mean a couple of feet of thick copper cable, something in milli-ohms or the like.